Pressure Transducers for Manned Spacecraft
All Categories
In addition to our customers making ΔP measurements across an orifice with our differential transducers, Tavis makes very accurate flow sensors with integral venturi tubes. In fact, the Space Station is chock full of Tavis flowmeters for environmental control and life support systems. Our Variable Reluctance technique and construction allow for very high line pressures even with low flow rates. Some of our more customized flowmeters have dual flow range capability.
Tavis Venturi flowmeters are used in applications with characteristics such as:
Tavis Venturi flowmeters are used in applications with characteristics such as:
- Custom venturi designs for specific flow requirements
- Dual gage low/high flow rates
- High line pressure
- Output signal linear with either pressure or flow
- No rotating/moving parts
- Continuous analog output; flow is not sampled or digitized
- Weld-mount, flange-mount, fitting-mount interface with system plumbing
- 4 - 20 mA and 0/1-5 VDC outputs
Unit of Measure
Items |
/Asset/10429.JPG 10429 |
/Asset/10474.JPG 10474 |
/Asset/10465.JPG 10465 |
/Asset/10507.JPG 10507 |
||||
Flow Range1 | N/A (1 psid loss at max flow) 0 - 3.5 gpm | N/A (1.1 psid loss at max flow) 500 - 1876 lb/hr1180 - 3100 lb/hr | N/A (0.97 psid & 1.42 psid loss at max flow) 498 - 3108 lb/hr705 - 4409 lb/hr | N/A (0.4 psid loss at max flow) 100 - 500 340 - 1700 800 - 4000 1000 - 5000 lb/hr | ||||
Line Pressure | N/A 65 psia | N/A 10 to 110 psia | N/A 17.8 to 121 psia25 to 171 psia | N/A 18 to 23 psia2 to 25 psia | ||||
Line Proof Pressure | N/A | N/A >172 psig | N/A 182 psia256 psig | N/A | ||||
Line Burst Pressure | N/A | N/A >200 psig | N/A 304 psia341 psig | N/A | ||||
Sensor Type | N/A Variable Reluctance | |||||||
Weight | N/A Max 30 oz | N/A Max 4.20 lb | N/A Max 3.31 lb | N/A Max 60 oz | ||||
Wetted Materials | N/A 17-4 PH SST 410 SST | N/A 17-4 PH SST 304L/321 CRES Inconel 600/625 | N/A 17-4 PH SST 321 CRES | N/A 17-4 PH SST 304L/321 CRES | ||||
Construction | N/A Bolt-on Venturi/Tube Assy, O-ring Seals, Metallic Diaphragm | N/A TIG Welded Gage/Venturi Assy, Custom Flange Mount | N/A TIG Welded Gage/Venturi Assy | N/A Bolt-on Venturi/Tube Assy, O-ring Seals, Metallic Diaphragm | ||||
Fittings / Ports | N/A 1/2" Flared Tube Fitting | N/A .90" DIA Inlet/Exit w/Custom Flange Mount | N/A .75" DIA Inlet/Exit | N/A Wiggins W903B16C Tube Connectors | ||||
Input Voltage | N/A 20 - 40 VDC | N/A Dual Input 15 VDC (each flow circuit) | N/A 24 - 32 VDC | N/A 20 - 40 VDC | ||||
Output Signal | N/A 0.0 - 5.0 VDC (linear with venturi ΔP) | N/A Dual Output : 4 - 20 mA (each flow circuit linear with venturi ΔP) | N/A 0.8 - 5.0 VDC (linear with flow) | N/A 0.2 - 5.0 VDC (linear with venturi ΔP) | ||||
Power/Current | N/A Max 10 mA | N/A 23 mA Max (each flow circuit) | N/A Max 25 mA | N/A Max 10 mA | ||||
Electrical Interface | N/A MS3116 (10-6) Connector | N/A NATC09Y11P35PB 13-Pin | N/A Mates with D38999/2611-98SN 6-Pin | N/A PT1H-10-6P | ||||
Reverse Polarity Protection | N/A Yes | |||||||
Isolation | N/A >100 MΩ @ 100 VDC | N/A | N/A >50 MΩ @ 100 VDC | N/A >100 MΩ @ 100 VDC | ||||
Output Impedance | N/A ≤100 Ω | N/A | N/A ≤150 Ω | N/A ≤1000 Ω | ||||
EMI | N/A | N/A capacitor filter per flow circuit | N/A Inductor/ Capacitor Filter | N/A | ||||
Compensated Temps | N/A -65 °F to +165 °F (Operating -65 °F to +200 °F) | N/A 33 °F to +122 °F (Fluid) -67 °F to +200 °F (Non-Operating) | N/A 33 °F to +103 °F -49 °F to +149 °F (Non-Operating -65 °F to +180 °F) | N/A -38 °F to +135 °F | ||||
Vibration | N/A 20 g pk to 2000 Hz | N/A 4.4 grms | N/A 26 grms | N/A 20 g pk to 2000 Hz | ||||
Shock | N/A 20 g 11 ms Half Sine | N/A | N/A | N/A 100 g 11 ms Half Sine | ||||
App Media | N/A JP-4/JET A | N/A Water | N/A Water Flourinert | N/A JP-4/JET A | ||||
Static Error Band2 | N/A ±0.5% FSO | N/A | N/A | N/A | ||||
Thermal Error2 | N/A ±2.0% FSO Max | N/A | N/A | N/A | ||||
Total Error Band (TEB)2 | N/A | N/A ±5% of Flow Rdg | N/A ±5% of FS Flow @ 16% Flow, Decreasing to ±2.5% of FS Flow at 40% Flow to 100% Flow | N/A ±5% FS @ 20% Flow, Decreasing to ±1% FS @ 100% Flow | ||||
Frequency Response3 | N/A Flat ±5% to 250 Hz | N/A | N/A 1 s (10% to 90% Step Input) | N/A | ||||
|