Standard / Non-Custom Transducers
>
Sample Product P110C
larger image
Sample Product P110C, Model P110C Absolute or Sealed Pressure Transducer
The Model P110C variable reluctance absolute or sealed pressure transducer is designed specifically for the petro-chemical industry. All welded construction reduces long term drift and hysteresis and increases accuracy. The pressure cavity is designed with no entrapment areas to facilitate cleaning. This unit features Tavis Corporations highly stable, reliable, accurate 4 to 20 mA electronics.
General Specifications
·
Electrical
·
Performance
·
Environmental
·
Features
General Specifications
Pressure Range
0 to 100 through 0 to 10000 psi
Proof Pressure
200% F.R. to 10000 psi max.
Sensor Type
Variable Reluctance
Media
Liquids or gases compatible with 17-4 PH SS
External Materials
17-4 PH and 300 Series SS
Electrical
Input Voltage (At the Transducer)
17 to 50 VDC
Power Supply Voltage
Transducer Input Voltage + (0.02 x load)
Output Voltage
4 to 20
mA
Max. Output Noise
1.0% F.S. peak
Load Resistance
(min. Supply voltage - 17) ˜ 0.02
Insulation Resistance
100 megohms min. at 100 VDC
Adjustment Range
Span: ± 2% F.S. min.
Zero: ± 2% F.S. min.
Performance
Static Error Band
Ranges 5000 psi and up : ± 0.5% F.S. max.
Ranges less than 5000 psi : ± 0.2% F.S. max.
Max. Temperature Error
± 0.75% F.S.
Max. Regulation
0.025% F.S. per volt
Environmental
Temperature Range
Compensated: 30ºF to +130ºF
Operating: -65ºF to +185ºF
Vibration
35 g s Peak to 2000 Hz
Shock
100 g s, Peak to 11 ms
Humidity, Rain, Fungus, Sand and Dust
Unaffected
Features
High Accuracy
Long Term Stability
Cleanable