Sample Product P110C, Model P110C Absolute or Sealed Pressure Transducer



The Model P110C variable reluctance absolute or sealed pressure transducer is designed specifically for the petro-chemical industry. All welded construction reduces long term drift and hysteresis and increases accuracy. The pressure cavity is designed with no entrapment areas to facilitate cleaning. This unit features Tavis Corporations highly stable, reliable, accurate 4 to 20 mA electronics.




General Specifications  · Electrical  · Performance  · Environmental  · Features

General Specifications

Pressure Range

0 to 100 through 0 to 10000 psi

Proof Pressure

200% F.R. to 10000 psi max.

Sensor Type

Variable Reluctance

Media

Liquids or gases compatible with 17-4 PH SS

External Materials

17-4 PH and 300 Series SS


Electrical

Input Voltage (At the Transducer)

17 to 50 VDC

Power Supply Voltage

View
Transducer Input Voltage + (0.02 x load)

Output Voltage

4 to 20 mA

Max. Output Noise

1.0% F.S. peak

Load Resistance

(min. Supply voltage - 17) ˜ 0.02

Insulation Resistance

100 megohms min. at 100 VDC

Adjustment Range

Span: ± 2% F.S. min.
Zero: ± 2% F.S. min.


Performance

Static Error Band

View
Ranges 5000 psi and up : ± 0.5% F.S. max.
Ranges less than 5000 psi : ± 0.2% F.S. max.

Max. Temperature Error

View
± 0.75% F.S.

Max. Regulation

0.025% F.S. per volt


Environmental

Temperature Range

Compensated: 30ºF to +130ºF
Operating: -65ºF to +185ºF

Vibration

35 g s Peak to 2000 Hz

Shock

100 g s, Peak to 11 ms

Humidity, Rain, Fungus, Sand and Dust

Unaffected


Features
  • High Accuracy
  • Long Term Stability
  • Cleanable
  • Stable Calibration